NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-030-1357 Item Description: Reactor | 5950 | 010301357 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Emi-F-0247 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3 875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0 500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0 135 INCHES NOMINAL SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 190 00 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING AND 310 00 MICROHENRIES MAXIMUM SINGLE COMPONENT ALL WINDING |
ACZB | FREQUENCY RATING | 400 0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4 250 INCHES NOMINAL |
ADAT | BODY WIDTH | 1 000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1 250 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 3 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5 0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0 090 SINGLE COMPONENT ALL WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |