NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-311-5637 Item Description: Power Supply Set | 6130 | 013115637 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ACM 3X100WITHOSCD 3 45 2000 E | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 28.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AN/ALQ-172; NSN4920-01-207-7057 |
ANPM | INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 187.2 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 228.8 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 60.0 HERTZ MINIMUM SINGLE POWER OUTPUT AND 400.0 HERTZ MAXIMUM SINGLE POWER OUTPUT |
CBBL | FEATURES PROVIDED | AC VOLTMETER |
CWGH | OUTPUT CURRENT RATING | 3000.0 AC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT |
CWGN | OUTPUT PHASE | THREE SINGLE POWER OUTPUT |
APNX | INPUT VOLTAGE RATING | 108.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 132.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | POWER SUPPLY COMES PKGD IN FOUR BOXES |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
CWHM | INPUT CURRENT RATING | 23.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |