| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5945-00-755-4354 Item Description: Relay Electromagnet | 5945 | 007554354 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 9274 5237 | 2 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 2.300 INCHES MAXIMUM |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.250 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | III CUBIC MEASURE | 18.630 CUBIC INCHES |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC LAMP LOAD AND 6.0 AMPERES DC LAMP LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SECOND MOUNTING FACILITY |
| APNQ | ARC QUENCHING METHOD | AIR |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
| TTQY | TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |
Warrantied inventory at competitive prices
Search the world's largest inventory of electronic components by manufacturer, category or part number