NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-040-0086 Item Description: Power Supply | 6130 | 010400086 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
L0t-W-5152-A | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.875 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 210.0 AC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -15.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.8 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+60.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -400.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND -1.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 6.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES MINIMUM 1ST POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 1ST OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 2ND OPERATING POWER RQMT |
Warrantied inventory at competitive prices